8 Kanal Meßverstärker mit automatischen Nullabgleich für DMS, Verstärkung 10 - 100 -1000 über Steckbrücken programmierbar (DMS), Sensorspeisung über Steckbrücken programmierbar 4V, 8V (DMS), Ausgang max. +/-5V über BNC, Eingang über 6 poligen Lemo Stecker, Stromversorgung 10-30 V DC.
SC-8 - Mobile sensor amplifier
8 channel signal conditioning unit, mixed installation practicable with modules for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER !
|
|

|
·
Signal conditioning for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER !!
·
STG excitation + 4 or 8 V !!
·
Dimensions: 65 x 105 x 250 mm, Weight 1.5kg !!
·
Per jumper selectable gain for STG and LVDT !
·
Power 10-30 VDC !
·
Mixed installation practicable, 1 up to 8 modules !
·
Full-, half- or quarter-bridges !
·
Easy handling
·
Auto Zero balancing of STG
|
|
|

Front - Inputs
|
|

Rear - Outputs +/-5V
|
|
|
Signal conditioning modules |
 |
To measure: |
Module |
Description |
Characteristics |
| Force, pressure,
strain,
torsion,
material stress |
STG |
Strain gauges |
- Full, half, quarter bridges in 2- and 3-wire technique
(120W , 350W , 1kW
)
- Setable gain (10, 100, 1000)
- Setable bridge supply (4V, 8V)
- Offset calibration with potentiometer or Auto Zero
-
Signal conditioning for STG
(strain gages)
-
Output voltage range ± 5V, I max = 5mA
-
Linearity error ± 0.1%
|
| distance |
LVDT |
Inductive
distance sensor |
- Setable gain (1, 2, 5, 10)
- Sensor supply 5kHz, 2.5V
- Offset calibration with potentiometer
|
| Frequency, speed
by pulse frequency |
F/V |
Frequency-to-voltage
converter |
- Setable maximum frequency (500Hz, 2.5kHz, 10kHz)
- Minimum frequency 40Hz
- Signal amplitude 0.3-10V
- Square, sine and triangle wave forms
- 10Hz output filter (2pol. Butterworth)
|
| Acceleration, oscillation, vibrations |
ACC |
Acceleration
sensor based on STG |
- all common sensors
- Setable gain 0.5, 1, 2, 4, 8, 16, 32
- Setable current 1mA, 2mA, 4mA, 20mA
- Linearity error +/-1%
- Excitation voltage 30V max
- Signal band width 5 – 16000Hz
|
| CAP |
Capacitance
accelerometer |
| ICP |
Piezoelectric
accelerometer |
| Temperature |
THERMO |
Thermo wires Type
J, K (T) |
- Measuring range from -20°C up to +600°C
- Gain 10mV/°C
- Internal cold junction compensation
- Optional galvanic isolation with integrated ISO module
|
| galvanic
isolated voltage |
ISO |
Isolation
amplifier |
- Additive isolated sensor excitation
- Optional 4Hz fixed filter (4pol. Butterworth)
|
| Current |
CUR |
Current-to-voltage
converter |
- Input current 0-20mA
- Input impedance 125W
- Bridge excitation 12V
|
| |
FILTER |
Optional filter
for all modules |
- 8th order elliptical or linear phase frequency response, more than 2000 cut