DA-PCM HS recorder is a
special development only for record and replay of PCM coded data streams, with additive
speech comments or IRIG B time code.First mode:
The most flexible method is available when PCM data and a pulse clock are present at
the encoder. In this case each different PCM coded data can be recorded and reproduced
with a data rate of 80 up to 1280 kbit/s.
Second mode: (OPTION)
When only the PCM coded data without clock is provided form the encoder, record an replay
is only possible with a corresponding option. In this case is only one bit rate for a
special PCM code possible. Please inform us about the desired bit rate and PCM code when
order.
Bit rate:
The maximum bit rate of 1280 kbit/s is only possible, if the bit rate and the clock
have the same frequency. For some PCM codes such as e. g. Miller code the double clock
rate is limited to a maximum of 640 kbit/s. This fact also concern mode one and two.Record
of speech and IRIG B time code information.
Independent of the measured data (PCM data), speech or IRIG B time code information
can be recorded. (Please fix your choice when order, because only one mode can be
installed). IRIG B time code will be only recorded and replayed in a modulated format. A
display for IRIG B time on the recorder is not available.
Remote control
Additive to the normal DAT recorder handling buttons, there is an input for record
start/ duration available.
Via opto coupler (galvanic isolation) the pulse width (with a potential of 5 up to 30 V)
start and regulate the duration . The pulse must have a potential of 5 up to 30 V)
Tape deck function
Record - Play - Stop - Pause - Fast forward - Fast reverse