SC-8 Messverstärker
8 Kanal Meßverstärker mit automatischen Nullabgleich für DMS, Verstärkung 10 - 100 -1000 über Steckbrücken programmierbar (DMS), Sensorspeisung über Steckbrücken programmierbar 4V, 8V (DMS), Ausgang max. +/-5V über BNC, Eingang über 6 poligen Lemo Stecker, Stromversorgung 10-30 V DC.

SC-8 - Mobile sensor amplifier
8 channel signal conditioning unit, mixed installation practicable with modules for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER
!



· Signal conditioning for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER !!

· STG excitation + 4 or 8 V !!

· Dimensions: 65 x 105 x 250 mm, Weight 1.5kg !!

· Per jumper selectable gain for STG and LVDT !

· Power 10-30 VDC !

· Mixed installation practicable, 1 up to 8 modules !

· Full-, half- or quarter-bridges !

· Easy handling

· Auto Zero balancing of STG



Front - Inputs



Rear - Outputs +/-5V


Signal conditioning modules

To measure:

Module

Description

Characteristics

Force,

pressure,

strain,

torsion,

material stress

STG Strain gauges
  • Full, half, quarter bridges in 2- and 3-wire technique
    (120W , 350W , 1kW )
  • Setable gain (10, 100, 1000)
  • Setable bridge supply (4V, 8V)
  • Offset calibration with potentiometer or Auto Zero
  • Signal conditioning for STG (strain gages)

  • Output voltage range ± 5V, I max = 5mA

  • Linearity error ± 0.1%

distance LVDT Inductive distance sensor
  • Setable gain (1, 2, 5, 10)
  • Sensor supply 5kHz, 2.5V
  • Offset calibration with potentiometer
Frequency,

speed by pulse frequency

F/V Frequency-to-voltage converter
  • Setable maximum frequency (500Hz, 2.5kHz, 10kHz)
  • Minimum frequency 40Hz
  • Signal amplitude 0.3-10V
  • Square, sine and triangle wave forms
  • 10Hz output filter (2pol. Butterworth)
Acceleration, oscillation, vibrations ACC Acceleration sensor based on STG
  • all common sensors
  • Setable gain 0.5, 1, 2, 4, 8, 16, 32
  • Setable current 1mA, 2mA, 4mA, 20mA
  • Linearity error +/-1%
  • Excitation voltage 30V max
  • Signal band width 5 – 16000Hz

CAP Capacitance accelerometer
ICP Piezoelectric accelerometer
Temperature THERMO Thermo wires

Type J, K (T)

  • Measuring range from -20°C up to +600°C
  • Gain 10mV/°C
  • Internal cold junction compensation
  • Optional galvanic isolation with integrated ISO module
galvanic isolated voltage ISO Isolation amplifier
  • Additive isolated sensor excitation
  • Optional 4Hz fixed filter (4pol. Butterworth)
Current CUR Current-to-voltage converter
  • Input current 0-20mA
  • Input impedance 125W
  • Bridge excitation 12V
FILTER Optional filter for all modules
  • 8th order elliptical or linear phase frequency response, more than 2000 cut off frequencies from 10Hz to 7,5kHz available (reciprocal scaling)

 