KMT - GmbH
  Startseite »
   Kategorien
Automotive
Messverstärker
Robuste Meßdatenrekorder
Software
Telemetriesysteme
PDFs
    Informationen
Worldwide
Impressum
Referencen
Messen
Company
Kontakt
    Sprachen
English Deutsch
SC-4M
4 channel signal conditioning unit, mixed installation practicable with modules for STG, LVDT, ISO, THERMO, F/V, ICP, FILTER, Excitation 2 ranges by use of jumpers (4 or 8 V), Gain: 3 ranges by use of jumpers (10, 100 or 1000), Zero balancing of STG via potentiometer, Full-, half- or quarter-bridges SC-4/M - Mobile Sensor amplifier 4 channel signal conditioning unit, mixed installation practicable with modules such as Straingauge, LVDT, Thermocouples, F/V conve

SC-4/M - Mobile Sensor amplifier
4 channel signal conditioning unit, mixed installation practicable with modules such as Straingauge, LVDT, Thermocouples, F/V converter and more.
!



· Signal conditioning for straingauge, displacement, vibration, shock, temperature .... !!

· STG excitation + 4 or 8 V !!

· Easy handling !

· Full-, half- or quarter-bridges !

· Mixed installation practicable, 1 up to 4 modules !

· Power 9-18 or 18-32 VDC !

· Per jumper selectable gain for STG and LVDT

· Size 140x180x25 mm



Technical data

SC-4/M consist of:
Basic housing with motherboard for max. 4 signal conditioning modules
DC/DC converter for power input of 9-18 or 18-32 VDC
Size 130x180x35 mm
Weight incl. 4 signal conditioning modules 900g


Signal conditioning modules

To measure:

Module

Description

Characteristics

Force,

pressure,

strain,

torsion,

material stress

STG Strain gauges
  • Full, half, quarter bridges in 2- and 3-wire technique
    (120W , 350W , 1kW )
  • Setable gain (10, 100, 1000)
  • Setable bridge supply (4V, 8V)
  • Offset calibration with potentiometer
  • Additive 5kHz fixed filter (2pol. Butterworth)
distance LVDT Inductive distance sensor
  • Setable gain (1, 2, 5, 10)
  • Sensor supply 5kHz, 2.5V
  • Offset calibration with potentiometer
Frequency,

speed by pulse frequency

F/V Frequency-to-voltage converter
  • Setable maximum frequency (500Hz, 2.5kHz, 10kHz)
  • Minimum frequency 40Hz
  • Signal amplitude 0.3-10V
  • Square, sine and triangle wave forms
  • 10Hz output filter (2pol. Butterworth)
Acceleration, oscillation, vibrations ACC Acceleration sensor based on STG
  • all common sensors
CAP Capacitance accelerometer
ICP Piezoelectric accelerometer
Temperature THERMO Thermo wires

Type J, K (T)

  • Measuring range from -20°C up to +600°C
  • Gain 10mV/°C
  • Internal cold junction compensation
  • Optional galvanic isolation with integrated ISO module
galvanic isolated voltage ISO Isolation amplifier
  • Additive isolated sensor excitation
  • Optional 4Hz fixed filter (4pol. Butterworth)
Current CUR Current-to-voltage converter
  • Input current 0-20mA
  • Input impedance 125W
  • Bridge excitation 12V
FILTER Optional filter for all modules
  • 8th order elliptical or linear phase frequency response, more than 2000 cut off frequencies from 10Hz to 7,5kHz available (reciprocal scaling)

 
Datenblatt PDF       Bedienungsanleitung PDF       Anwendungsbeispiele PDF 


Copyright © 2011 KMT - Messtechnik & Telemetrie, Telemetry - KMT Telemetry solutions for Telemetrie
Design by Kerndl IT Service
Powered by osCommerce