Kategorien |
 |
|
| |
Informationen |
 |
|
|
|
| |
Languages |
 |
|
|
|
 |
|
 |
|
|
 |
D-2/4 - mobile mini DAT recorder
Smallest 4 channel DAT recorder of world
for record and playback form analog signals up to 16 kHz per channel in 2 channel mode. |

|
- Record and reproduce of 4 analog data
channels, voice, date, time and digital signals.
- Extremely small and ruggedized design and
therefore multiple application areas
- Usable in each position and therefore
especially suitable for extreme mobile applications
- Very resistant against shock and vibrations
- Extremely adaptable to various measuring
requests due to switchable number of channels and signal bandwidth
- Robust remote control box with bargraph
display
- Computer interface for on- and off-line Data
analysis (OPT.)
- Telemetry connection for computer interface
for on-line data analysis during mobile use (OPTION)
- Event-driven record commands
- Record commands by Remote Control
- Automatic test number recording
- Fast search run in both directions
- Power supply DC 10 ... 18 V or 18 ... 32V,
battery (OPTION), mains 220 V AC (OPTION)
|
The D-2/4 DAT Recorder is small and
powerful. The physical size has a major advantage over larger units. Due to the small
mechanical dimension it can be. This becomes apparent, whenever space or critical
positioning is the issue. Good examples are the cramped quarters of building and
earth-moving machines, cars and planes. The surveillance's and analysis is done On-line.
A telemetry output, connected to our RF telemetry TS/TE 2.5, transmits the data to a
computer. Concurrently, high redundancy recording of raw data takes place within the DAT.
With the aid of our REMUS Software all or single channels can be selected and/or
presented. The computer freed from the ''Data Logging" task can now be utilized for
analysis and presentation.
The ''Record Commands" can be controlled remotely. The "Record Procedure"
is started and terminated with the +5 V and 0 V levels respectively.
Sometimes, especially during long term measurements, continuous recording would be
impractical. In this case the ''Event-Driven" record control is a powerful tool.
Supporting this feature is one "Event Channel". Once an ."Event
Channel" is activated, a ''Record Procedure'' of approximately 1 minute is started.
This procedure includes the recording of the active event, time and test number.
The D-2/4 DAT can convert data from analog to digital and feed them into computer directly
without recording. For this operation the "Tape Bypass" function is used. Just
as in recording mode the analog data are filtered and digitized. The data are transferred
directly to the computer instead to tape.
This is independent upon the tape runs and records data or stays without recording.
In this mode the DAT recorder is used as PCM encoder for telemetry transmission.
Another feature is the pulse input DIG In/Out. With that feature any pulses with any
sampling relationship from 0 to 40 kHz can be recorded and reproduced. This input is very
suitable for PCM signals transmitted via RF telemetry. Data from PCM encoders, input
pulses from sensors for revolution or speed, or the recording of simple events are just a
few. Optionally an event multiplexer for 16 events is available.
These are some examples of the flexible use of our Data Recorder D-2/4. For more
information contact our sales office. |
References: (D-2/16 and D-2/4) |
Aprilia motorcycle Italy |
Benetton Formula 1 England |
CNES France
MIR Space Sation |
Daewoo Corp. Korea |
Ferrari Formula 1 Italy |
Fiat Italy |
Renault Sport France |
SAGEM France |
Samsung Heavy Industry
Korea |
Hyundai Korea |
Military test departments |
Railway Germany |
VW Brazil |
and many more .... . |
|
References: (D-2/16, D-2/8 and D-2/4) |
Missile
(D-2/16) |
 |

|
Missile
(D-2/4) |

|
MIR
Space Station
(D-2/8 Spec.)
CNES
France |

 |

 |
Technical
data: |
- 4 analog channels; input and output are connected via BNC
connectors
- Measuring range +/-5 V with overload indication for each
channel
- Resolution 12 Bit, simultaneous sampling of all channels
- Input impedance 100 KOhm, SNR 72 dB
- Over voltage protection +40 V
- Total sampling rate 96 kHz, distributed to selected number of
channels ( see table )
- 8-pole lowpass Butterworth filter for input and output,
avoiding Aliasing effects and smoothing the output signals; damping in locking area 48
dB/Octave
- Analog output impedance 2 Ohme, max. 10 mA, +/-5V
- Programmable for 2 - 4 channel mode
- Signal bandwidth max. in 2 channel mode 0 ... 16 kHz (-3dB)
- Serial Interface, suitable for direct transmission even over
long cables or for RF- or IR-transmission
- PC Interface plug-in board for all IBM comp. PCs (Option)
- Digital pulse input (TTL), that means pulses from 0 ... 40 kHz
can be recorded and reproduced.
- Date and time recording (year- month - day - hour - minute -
second)
- Tape length counter for absolute time, programming time,
remaining record time.
- Automatic or manual setting of test number
- Fast search run in both directions searching the test number
- Remote control unit with bargraph display, Voice channel and
overload indication (option)
- Voice channel with external microphone and built-in
loudspeaker, signal bandwidth 60 ... 2800 Hz.
- Recording time 3 hours with a DT180 cassette
- Storing capacity approximate, 2.4 Giga Byte with a DT180
cassette Reproducible accuracy between record and replay at 0 Hz +0,1 %
- Phase error between channels at same frequency <1°.
- Error correction system Double Encoded Reed Solomon Code.
- Bit error rate better 10-10
- Recording format Helical Scan R-DAT
- Illuminated display with following indications: date/time -
program ie. test number - tape length counter for absolute time - program time - remaining
record time - indications for functions like record -forward - reverse - tape loaded etc.
- Additional indications like battery level - error condensing
water
- Functional buttons on tape deck: FORWARD - REVERSE - PLAY -
RECORD -STOP - PAUSE - HOLD
- Remote controllable with TTL-level for START/REC - STOP or/and
event controllable with 1 event for blocs of 1 min
- Power supply DC 10 ... 32 V, battery (Option) or mains 220 V
+/-10 % AC (Option) 110V AC (Option)
- Power requirement approximate 10 Watt
- Environmental conditions:
Operating temperature range -5 C° to + 45 °C
Storage temperature range -20 °C to + 60 °C
Relative humidity 20 ... 80 % non condensing
Vibration 5g Mil. Standard 810 C, Curve C
Shock 10g in all directions
Size 157 x 90 x 65 mm without shock absorber
Weight 1.3 kg without shock absorber
- 16 analog channels; input and output are connected
via BNC connectors
- Measuring range ~5 V with overload indication for each channel
- Resolution 12 Bit, simultaneous sampling of all channels
- Input impedance 100 KOhm, SNR 72 dB
- Over voltage protection +40 V
- Total sampling rate 96 kHz, distributed to selected number of
channels ( see table )
- 8-pole lowpass Butterworth filter for input and output,
avoiding Aliasing effects and smoothing the output signals; damping in locking area 48
dB/Octave
- Analog output impedance 2 Ohme, max. 10 mA, +/-5V
- Programmable for 2 - 4 - 8 - 16 channel mode
- Signal bandwidth max. in 2 channel mode 0 ... 16 kHz (-3dB)
- Serial Interface, suitable for direct transmission even over
long cables or for RF- or IR-transmission
- PC Interface plug-in board for all IBM comp. PCs (Option)
- Digital pulse input (TTL), that means pulses from 0 ... 20 kHz
can be recorded and reproduced.
- Date and time recording (year- month - day - hour - minute -
second)
- Tape length counter for absolute time, programming time,
remaining record time.
- Automatic or manual setting of test number
- Fast search run in both directions searching the test number
- Remote control unit with bargraph display, Voice channel and
overload indication (option)
- Voice channel with external microphone and built-in
loudspeaker, signal bandwidth 60 ... 2800 Hz.
- Recording time 3 hours with a DT180 cassette
- Storing capacity approximate, 2.4 Giga Byte with a DT180
cassette Reproducible accuracy between record and replay at 0 Hz +0,1 %
- Phase error between channels at same frequency <1°.
- Error correction system Double Encoded Reed Solomon Code.
- Bit error rate better 10-10
- Recording format Helical Scan R-DAT
- Illuminated display with following indications: date/time -
program i.e. test number - tape length counter for absolute time - program time -
remaining record time - indications for functions like record -forward - reverse - tape
loaded etc.
- Additional indications like battery level - error condensing
water
- Functional buttons on tape deck: FORWARD - REVERSE - PLAY -
RECORD -STOP - PAUSE - HOLD
- Remote controllable with TTL-level for START/REC - STOP or/and
event controllable with 1 event for blocs of 1 min
- Power supply DC 10 ... 32 V, battery (Option) or mains 220 V
+/-10 % AC (Option) 110V AC (Option)
- Power requirement approximate 10 Watt
- Environmental conditions:
Operating temperature range -5 C° to + 45 °C
Storage temperature range -20 °C to + 60 °C
Relative humidity 20 ... 80 % non condensing
Vibration 5g Mil. Standard 810 C, Curve C
Shock 10g in all directions
Size 160 x 90 x 90 mm without shock absorber
Weight 1.5 kg without shock absorber
|
Table: |
| |
Analogue bandwidth
kHz -3 dB |
Scanning rate
kHz |
Channel
Mux |
2 CH. |
4 CH. |
2 CH. |
4 CH. |
max.
3 hours |
16 kHz |
8 kHz |
48 kHz |
24 kHz |
|
|
| | Datasheet PDF User manual PDF Application samples PDF  |
|
|
|
|